ON-SITE LEAK SEALING

We address leaks in industrial facilities without the need to shut down the system, working under normal operating pressure and temperature conditions whenever the facility allows it.

When shutting down the plant is not an option

A leak in an industrial facility can result in product or energy loss and compromise system components, while stopping the plant for a conventional repair can directly affect production. Online leak sealing makes it possible to address certain leaks without immediately shutting down the process, reducing the impact of the intervention on plant operations.

Controlled intervention

The intervention begins by assessing the location and conditions of the leak to determine the appropriate method. Depending on the situation, a barrier or cavity is created around the affected area and a sealing compound compatible with the fluid and operating temperature is injected. The compound is injected in a controlled manner until the leak is contained.

SEALING ADAPTED TO EACH INSTALLATION

Online leak sealing does not follow a single procedure. The geometry of the component, the type of leak, and the system conditions determine both the containment method and the compound and injection technique to be used.

Flange injection

In flanged connections, the compound can be systematically injected around the flange. The procedure progresses from the point opposite the leak toward the affected area, progressively creating the barrier required to control the escape.

Packing

When a leak occurs through deteriorated or worn packing, a compatible compound can be introduced to replace the lost material and restore the packing gland's ability to maintain a seal.

Wire wrapping

In certain flange configurations with limited clearance, wire wrapping can be used to create a barrier around the joint. Depending on the service conditions, materials such as copper, stainless steel, or other alloys may be used.

Injection clamps and rings

Clamps can be used to create a sealed chamber around the affected area. Once installed, the sealing compound is introduced through injection points distributed around the device until the leak is controlled.

Injection rings and collars allow the same principle to be adapted to different geometries and situations, including installations where nearby obstructions are present around the area requiring intervention.

Injection boxes and enclosures

When the geometry of the installation requires greater coverage, specially designed enclosures can be used to surround the affected area. This method can be used to address leaks in welds, pipe sections, elbows, couplings, valves, and flanges.

The enclosure creates the necessary space to contain and inject the compound around the leak point.

Valves with fluid passage

Certain internal valve leaks can also be addressed by creating a small compound plug near the valve seat. This type of intervention requires a specific assessment of the valve and system conditions before its feasibility can be determined.

Sealing compound selection

The material used is not selected generically. The choice depends primarily on the chemical composition of the fluid and the temperature at the leak, ensuring that the compound is compatible with the specific service conditions.

Compounds used for this type of intervention are formulated to retain their volume once injected and maintain the barrier created around the leak.

Applications

Depending on the characteristics of each case, sealing techniques can be applied to flanges, valves, piping, welds, elbows, heat exchangers, joints, pipe fittings, and packing.

This allows the procedure to be adapted to different points throughout an installation rather than limiting the service to a single type of component.

Operating conditions

Reference technical documentation covers applications ranging from cryogenic conditions to temperatures above 815 °C (1500 °F) and from vacuum conditions to pressures exceeding 6,300 psi.

These values represent the range indicated for the sealing technology and do not mean that every leak can be treated under those conditions. Feasibility and procedure must be determined based on the specific characteristics of each installation.